JPM, Vol. 15, Pages 320: Clinical Outcomes of 3D-Printed Titanium Patient-Specific Implants in Lumbar Interbody Fusion: A Prospective Clinical Trial with a Systematic Review of Conventional Techniques
Journal of Personalized Medicine doi: 10.3390/jpm15070320
Authors:
Kevin A. Seex
Ralph J. Mobbs
Marc Coughlan
Matthew Pelletier
William R. Walsh
Jackson C. Hill
William C. H. Parr
Background: Lumbar Interbody Fusion (LIF) is a surgical procedure aimed at addressing a range of pathological conditions affecting the structure and function of the spine. Patient-Specific Interbody Cages (PSICs) are an emerging technology that are used in LIF; however, there is a lack of clinical outcome data, making it difficult to assess the potential risks, benefits, and value of PSICs. The purpose of this present study is to contribute data to the field on this new emerging technology. The aims were to investigate Quality of Life (QoL), pain, and the complications of PSICs in LIF. To provide a comparative cohort, we performed a systematic review of patient-reported outcomes of conventional fusion techniques. Methods: This study reports on a multi-surgeon, multi-centre clinical trial of patients with lumbar degenerative disc disease, necessitating discectomy and fusion. All patients underwent LIF procedures with 3D-printed PSICs. Pain Visual Analogue Scale (VAS) and QoL (EQ-5D) scores were collected pre-operatively and at 6m, 12m, and 24m post-operatively. For comparative purposes, we performed a systematic review of the VAS scores from traditional LIF cages and analysed the Australian Spine Registry QoL data. Results: The literature search yielded 4272 publications. The studies were subdivided into four groups based on the interbody device type. All the groups demonstrated improvements in the VAS (for back pain) scores post-operatively. In total, 78 patients (109 instrumented levels) underwent LIF procedures with 3DP PSICs. There were three reoperations (3.8%) and no revisions of any PSIC. The mean VAS scores improved significantly (p < 0.01) from 7.85 (1.50 SD) pre-operatively to 2.03 (2.13 SD) at 24 months post-operatively. The mean QoL index scores improved significantly (p < 0.01) from a pre-operative 0.257 (0.332 SD) to 0.815 (0.208 SD) at 24 months. Conclusions: The systematic review indicated that device fixation to the interbody space was associated with lower VAS scores. The results from the investigational cohort suggest that PSICs may represent a new progression in implant design for spinal fusion, with an associated clinical benefit for LIF.
Source link
Kevin A. Seex www.mdpi.com